Error Subcode Possible cause Possible solution
100 MDT application doesn't respond Update software via deadmanswitch (installation manual 7.3.1)
101 MDT application doesn't respond Update software via deadmanswitch (installation manual 7.3.1)
102 Updater started without the installation flag Repeat the update but initiate from the workshop
103 App-mode is not set Restart the MDT, contact Euphoria helpdesk.
300 Integrity failure in de MDT application Return the MDT to Euphoria
301 No update file found Check USB stick, re-insert it & try again
302 1 The update file has no name Check the usb-stick and try again
302 2 The destination of the update file is not a valid directory Contact Euphoria helpdesk and ask for a valid update file
302 3 The destination of the update file has not the correct permissions
302 4 The destination of the update file can’t be read
303 Problem with USB-stick Try again with a new USB-stick
304 1 The update file has no name Download the update file again, put it on the USB-stick and try again
304 2 The mountpoint has no name Download the update file again, put it on the USB-stick and try again
304 3 cryptDevice doesn’t exist (needed for decryption) Download the update file again, put it on the USB-stick and try again
304 4 Update file is 0 bytes in size Download the update file again, put it on the USB-stick and try again
304 5 Can’t open the update file Download the update file again, put it on the USB-stick and try again
304 6 The update file is not encrypted with LUKS (Linux Unified Key Setup) Download the update file again, put it on the USB-stick and try again
304 7 Initializing the decrypt of the update Download the update file again, put it on the USB-stick and try again
304 8 crypt_load failed Download the update file again, put it on the USB-stick and try again
304 9 Decryption with password failed. Download the update file again, put it on the USB-stick and try again
304 10 Retrieving information of the cryptdevice failed Download the update file again, put it on the USB-stick and try again
304 11 Unable to mount the encrypted file Download the update file again, put it on the USB-stick and try again
304 12 Failed to make a mountpoint for the encrypted file Download the update file again, put it on the USB-stick and try again
305 Some parts not installed Contact Euphoria helpdesk for suitable update file
306 Update file doesn’t contain packages Contact Euphoria helpdesk for suitable update file
307 Update file contains incorrect packages Contact Euphoria helpdesk for suitable update file
308 Internal problem on the MDT Return MDT to Euphoria
309 Integrity error Return MDT to Euphoria
312 Vehicle not authorised for update Update is not authorized for this specific vehicle, contact Euphoria helpdesk.
313 Update not allowed on current version
314 Unknown card Trustedpath not set or invalid update. Contact Euphoria helpdesk